CBGGM - AUTOMOTIVE GOOP, 35101013A

  • MSDS: CBGGM
  • Manufacturer: ECLECTIC PRODUCTS INC
  • Product Name: AUTOMOTIVE GOOP, 35101013A
  • National Stock Number: 8030-00N067644
Product Identification

Product ID:AUTOMOTIVE GOOP, 35101013A
MSDS Date:01/24/1994
FSC:8030
NIIN:00N067644
MSDS Number: CBGGM

Responsible Party
ECLECTIC PRODUCTS INC
CARSON, CA 90749-4566
US

Emergency Phone: 800-535-5053

Info Phone: 800-767-4667

Cage: EO292

Contractor
ECLECTIC PRODUCTS, INC.
2280 EUGENE, OR 97402 US

Telephone: 503-484-9621

Cage: EO292

Ingredients

ETHYLENE, TETRACHLORO-; (TETRACHLOROETHYLENE

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 67.50%

OSHA PEL 100 PPM

ACGIH TLV: 25 PPM; 100 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


7.53 LB/GAL (903 G/L)

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


SINGLE DOSE ORAL TOX IS

RTECS: 9999999ZZ


W/OTHER EFTS AS LISTED FOR INHAL. DO NOT INDUCE

RTECS: 9999999ZZ


SPONT OCCURING MALIGNANT TUMORS IN CERTAIN LAB RATS

RTECS: 9999999ZZ


TO SHOW TUMORIGENIC RESPONSE. EPIDEMOLOGY STUDIES

RTECS: 9999999ZZ


TETRACHLOROETHYLENE EXPOS & CANCER. DID NOT CAUSE

RTECS: 9999999ZZ


PRLNGD EXPOS ABOVE OSHA PEL MAY RESULT IN LIVER &

RTECS: 9999999ZZ


IF ASPIR & CAUSE SYSTEMIC EFTS, DECISION OF

RTECS: 9999999ZZ


IF LAVAGE IS PERFORMED, SUGGEST ENDOTRACHEAL &/OR

RTECS: 9999999ZZ


WEIGHED AGAINST TOX WHEN CONSIDERING EMPTYING

RTECS: 9999999ZZ


ABSOLUTLEY NEC. NO SPECIFIC ANTIDOTE. SUPPORTIVE

RTECS: 9999999ZZ


REACTIONS OF THE PATIENT.

RTECS: 9999999ZZ


PROT. VAPS WILL COLLECT IN LOW PLACES

RTECS: 9999999ZZ


NOT ENTER THESE AREAS UNLESS SPECIAL NIOSH/MSHA

RTECS: 9999999ZZ


GLOVES, BOOTS, APRON OR FULL BODY SUIT

RTECS: 9999999ZZ


BE EVALUATED BY MANAGEMENT TO DETERMINE PROPER

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (EG, EPINEPHRINE) MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE-SUSTAININ G USES IN HUMANS
ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS . INHAL: DIZZ MAY OCCUR
AT 200 PPM; (EFTS OF OVEREXP)
Explanation of Carcinogenicity:TETRACHLOROETHYLENE: IARC MONO, SUPP,
VOL 7, PG 355, 1987:GROUP 2B. NTP 7TH ANNUAL REPORT ON CARCINS,
1994: (SUPDAT)
Effects of Overexposure:HLTH HAZ: PROGRESSIVELY HIGHER LEVELS CAN CAUSE
IRRIT OF RESP TRACT, DRUNKENESS, NAUS, INCOORDINATION, UNCON & EVEN
ASPHY IN CONFINED POORLY VENT AREAS. EYES: PROD IN EYES CAN RSLT IN
DISCOMFORT, PAIN & IRRIT. VAPS MAY IRRIT AT ABOUT 100 PPM. SKIN:
IRRIT CAN DEVELOP FOLLOWING RPTD &/OR PRLNGD CNTCT & MAY CAUSE
(SUPDAT)
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN AND LUNG
CONDITIONS.

First Aid

First Aid:EYES: FLUSH W/WATER FOR AT LEAST 15 MIN. SEEK MED CARE IF
IRRIT PERSISTS/DEVELOPS. SKIN: WIPE FROM SKIN & WASH W/SOAP &
WATER. IF IRRIT DEVELOPS SEEK MED ATTN. INHAL: REMOVE TO FRESH AIR.
IF BRTHG IS DFCLT, GIVE OXYGEN. GIVE ARTF RESUSCITATION IF NOT
BRTHG. INGEST: DO NOT INDUCE VOMIT. CALL MD. GIVE 1 OR 2 GLASSES OF
WATER TO DRINK. NOTE TO MD: BECAUSE RAPID ABSORPTION MAY OCCUR THRU
LUNGS (ING 9)

Fire Fighting

Flash Point:NONE
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . COOL FIRE EXPOSED CONTAINERS WITH
WATER.
Unusual Fire/Explosion Hazard:PROD IS NON-FLAMM & NON-EXPLO UNDER NORM
CNDTNS OF USE. AT HIGH TEMPS, PROD DECOMPOSES TO GIVE OFF
HYDROCHLORIC ACID AS GAS PLUS OTHER TOX & IRRITATING (SUPDAT)

Accidental Release

Spill Release Procedures:SMALL LEAKS: WIPE UP OR SOAK UP IMMEDIATELY
WITH INERT MATERIAL. REMOVE TO OUTDOORS. LARGE SPILLS: EVACUATE
AREA; CONTAIN LIQUID; TRANSFER TO CLOSED METAL CONTAINERS; KEEP OUT
OF WATER SUPPLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:IN LG QTYS, LETHAL CONCS MAY EXIST IN
AREAS W/POOR VENT. DO NOT USE IN POORLY VENT OR CONFINED SPACES
W/OUT PROPER NIOSH/MSHA APPRVD RESP (ING 14)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:IF VENT IS INADEQ TO MAINTAIN TLV WEAR A
NIOSH/MSHA APPRVD AIR PURIFYING ORGANIC CARTRIDGE RESP. FOR EMER &
OVEREXP USE NIOSH/MSHA APPRVD POS PRESS SCBA. IN CONFINED/POORLY
VENT AREAS USE NIOSH/MSHA A PPRVD POS PRESS SCBA.
Ventilation:ADEQUATE VENT SHOULD BE PROVIDED TO KEEP VAP CONCS BELOW
ACCEPTABLE EXPOS GUIDELINES. USE ONLY W/ADEQUATE VENT.
Protective Gloves:NEOPRENE-LATEX GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . AS
NEC TO PVNT SKIN CNTCT. SELECTION OF SPECIFIC ITEMS SUCH AS (ING
16)
Work Hygienic Practices:DO NOT ALLOW EYE OR SKIN CONTACT. AVOID
BREATHING VAPORS. WASH THORO AFTER HANDLING & BEFORE EATING OR
DRINKING.
Supplemental Safety and Health
EXPLO HAZ: VAPS SUCH AS PHOSGENE & CHLORINE. IF STORAGE CNTNRS ARE
EXPOSED TO EXCESS HEAT, OVER-PRESSURIZATION CAN RSLT IN CNTNR
RUPTURE. EXPLAN OF CARCIN: ANTIC TO BE CARCIN. ANIMAL:LIVER TUMORS.
EFT S OF OVEREXP: DRYING/FLAKING OF SKIN. SINGLE PRLNGD EXPOS IS
NOT LIKELY TO RSLT IN MATL BEING ABSORBED THRU SKIN (ING 3)

Chemical Properties

Boiling Pt:B.P. Text:250F,121C
Vapor Pres:SEE ING
Vapor Density:HVR/AIR
Spec Gravity:1.3 (H*2O=1)
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NEGLIGIBLE
Appearance and Odor:VISCOUS LIQUID WITH ETHER-LIKE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND OXIDIZING MATERIALS. AVOID MIXING WITH CAUSTIC SODA OR
POTASH.
Stability Condition to Avoid:AVOID EXTREME HEAT, FLAME OR SPARKS. AVOID
CONTACT WITH ALUMINUM EQUIPMENT HAVING CONFINED SPACES (IE,
PUMPHOUSINGS)
Hazardous Decomposition Products:TOXIC/IRRITATING GASES AND FUMES:
HYDROGEN CHLORIDE, CARBON DIXOIDE, SIMPLE HYDROCARBONS, PHOSGENE
AND CHLORINE.

Disposal

Waste Disposal Methods:RECLAIM OR INCINERATE NON-HARDENED PRODUCT.
MATERIAL RESULTING FROM CLEAN UP OPERATIONS MAY BE HAZARDOUS WASTE
AND THEREFORE SUBJECT TO SPECIFIC REGULATIONS. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS AT TIME OF
DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.